Content Preview
TB039 Rev1 Setup Parameters on Safetronics Inverter
Objective
The purpose of this document is to provide the information needed to correctly setup the Safetronics inverter
for a Centroid CNC control
Safetronics PC3 Inverter Settings
Parameter No Value Units Description
00 Lock 1 Lock/Unlock Parameters
Unlock Use only to reset 2 8 Â
Resets unit to factory defaults
1 0000 Â Decelerate to Stop
2 Must be set with tach
to match max spindle
speed Hz Maximum Output Frequency
3 215 / 380 * VAC Maximum Voltage
9 3 sec Acceleration Time
10 1 0 to 3 0 sec Deceleration Time
Use one of these value
depending upon resistor
value 1 2 3 sec sec sec 30 ohm 200watt resistor 45 ohm
200 watt resistor If you get inverter
faults
19 8 5 max 14 1 max A A Motor Current for 3HP Motor Motor
Current for 5HP motor
26 100 % rated current
of inverter DC Injection Braking Current
27 0 1 sec DC Injection Braking Time at Stop
28 0 sec DC Injection Braking Time at Start
* Installer must determine Saftronics
1 800 533 0031 Yaskawa
1 847 291 6219
Using the front panel keys to edit parameters
Start by pressing the PROGRAM/DRIVE button Drive LED will go out
Use the [^] and [v] arrows to set parameter number
Press [ENTER] to enter into edit mode
The values will flash Use > to change a digit
Use the [^] and [v] arrows to increase and decrease values
Press [DSPL] to escape
Tips Do not
press the LOCAL/REMOTE key the LED FWD should be off SEQ REF on
Yaskawa 616PC5 and 616G5 models use similar settings
Document History
Rev1 Created on 1998 03 23