Content Preview
TB255 Rev1 Yaskawa VS 616G3 Inverter Setup
Â
Setup parameters on Yaskawa Inverter
Objective
The purpose of this document is to provide the information needed to correctly setup the Yaskawa inverter for a Centroid CNC control
Yaskawa VS 616G3 Inverter Settings
Parameter No Value Units Description
bn 01 3 sec Acceleration Time
bn 02 1 5 depending upon braking resistor sec Deceleration Time
Sn 03 0000 Set and read parameters
1110 Master reset
2 wire  Password parameter selection / initialization
Sn 04 0000 Master frequency reference
by analog input
External terminal operation
Ramp to stop  Operation method select
Â
Â
Â
Â
Stopping method select
Cn 01 Depends on input voltage VAC Input voltage
Cn 02 Must be set with tach to match max
spindle speed Hz Maximum Frequency
Cn 03 Depends on motor VAC Maximum voltage
Cn 09 Depends on motor A Motor current
All other parameters are set to factory default
Â
Â
Wiring connections
L1 R L2 S L3 T 3 phase power in
1 Forward
2 Reverse run
4 Fault reset
11 Input common
13 Master speed frequency reference 0 10vdc
17 Frequency reference common
18 Fault output normally open
20 Fault output common
T1 U T2 V T3 W Motor voltage out
B1/+ B0/ Braking resistor
Â
Document History
Rev1 Created on 2012 01 09
by #358