Content Preview
TB184 Rev1 Heating and Cooling Parameters for SD drives
Overview
This document covers the new heating and cooling parameters for the original SD drives and the new SD
drives with the finned heatsink These parameters are necessary to protect the SD drives from over heating
Procedure
These parameters are set by going to the Parameter screen in the Configuration menu
Press F1 Setup
from main screen F3 Config
enter default password 137 Enter
and F3 Params
Then
enter the values according to your drive and motor configuration
ÃÂ
AC Brushless Motors and Drives
Parameter Axis Values Values Values Values Values
SD Drive ÃÂ SD3 SD1
750W
motors SD3 SD1
1&2kW
motors SD3 SD1 finned
heatsink 1&2kW
motors SD1 45A finned
heatsink 3kW
motors SD1 45A finned
heatsink 4kW
motors
20 N/A 72 72 72 72 72
21 X 0 05 0 5 0 23 0 23 0 23
22 Y 0 05 0 5 0 23 0 23 0 23
23 Z 0 05 0 5 0 23 0 23 0 23
24 4th 0 05 0 5 0 23 0 23 0 23
25 X 0 68 9 0 12 0 12 0 14 5
26 Y 0 68 9 0 12 0 12 0 14 5
27 Z 0 68 9 0 12 0 12 0 14 5
28 4th 0 68 9 0 12 0 12 0 14 5
29 ALL 150 150 150 150 150
30 ALL 180 180 180 180 180
132 5th 0 05 0 5 0 23 0 23 0 23
136 5th 0 68 9 0 12 0 12 0 14 5
ÃÂ
Make sure to reference Tech Bulletin 44 for the correct PID and Drive settings
Document History
Rev1 Created on 2006 10 10