Content Preview
TB172 Rev1 Replacing a Toko Power Supply with a Cosel Power Supply
Overview
This document covers how to hook up a Cosel power supply into an M15 control that previously used a Toko
power supply
Adapter Plate
Dimensions of Toko to Cosel adapter plate 2 1/2" X 5"
4 1/4" standoffs are required to mount the Cosel PS on the adapter plate
Wiring
1 The 110VAC input cable will need to be spliced into the existing black white and green wires
2 As for the 5 12 and ?12 VDC outputs the cable provided will plug directly into where the Toko did The
5VDC for the PLC will need to splice into the 5VDC coming from the Cosel PS
How to connect Cosel DC Power cable without drive connector
Document History
Rev1 Created on 2004 08 30