Overview
This document describes how to upgrade an existing M39 to an M39 with a variable spindle control Â
Materials List Â
Part Number Part Description
10142 Spin232 DB9TXS connector and fiber optic cable
1331 Cosel Power supply w/ metal cover and cables
3923 Estop Piggyback contactor
 Wire required to connect components
1 Connect the Cosel power supply and Spin232 rev B according to this diagram
Or connect the Cosel PS and Spin232 rev C according to this diagram
2 Make sure the jumpers are set correctly for the 0 10V on the Spin232 both rev 's
3 Now connect the VOUT terminal of the SPIN232 board to the 0 10V input of your inverter and the GND right
below VOUT to the inverter common
4 Connect the E Stop terminal of the Spin232C to the E Stop input of the PLC only if the PLC shares the
same power supply as the Spin232C and the input common is GND If not then you will need to connect a
jumper between the E Stop and GND terminal of the Spin232C
5 Mount the Estop piggy back to the Estop contactor Connect it and the rest of the inverter connections to the
PLC 15/15 according to the diagram below
6 Install the DB9TXS fiber optic adapter to the serial port COM1 or COM2 on the back of the PC and plug
the fiber optic cable into the adapter and the fiber optic socket on the SPIN232 board
7 Parameter 31 for spindle speed output port must be set to a 1 if the DB9TXS connector is plugged into
COM1 of the PC or 2 if connected to COM2 Parameter 32 for the baud rate must be set to 19200